مشخصات پژوهش

صفحه نخست /Urinary bio-monitoring of ...
عنوان Urinary bio-monitoring of aromatic amine derivatives by new needle trap device packed with the multi-component adsorbent
نوع پژوهش مقاله چاپ شده
کلیدواژه‌ها Aromatic amines, multicomponent adsorbent, Metal-Organic Framework, Zeolite
چکیده Aromatic amines are a large group of chemical compounds that have attracted the attention of researchers due to their toxicity and carcinogenicity. This study aimed to develop an efficient method for sampling and analysis of aromatic amines (Aniline, N, N-dimethylaniline, 2-chloroaniline, and 3-chloroaniline) from the vapour phase (headspace) of urine samples. For the implementation of this plan, a needle trap device packed with the three-component adsorbent consisting of nano-Hydroxy Apatite (nHA), Zeolite (Ze), and Metal–Organic Framework (MOF) equipped with GC-FID was employed for the first phase. Examination of the prepared adsorbents was performed by FT-IR, PXRD, and FE-SEM techniques. The optimal value of considerable parameters such as time and temperature of extraction, salt content, and pH were established using the Response Surface Methodology-Central Composite Design (RMS-CCD) method. In this way, the optimal extraction of targeted analytes was accomplished in 41 min at 41 °C with NaCl content of 33.0% (w/v) and pH: 13.0, respectively. Also, the repeatability and reproducibility of the method were calculated to be in the range of 2.2–7.1% and 3.9–8.1%, respectively, which indicates the acceptable precision of the method. Also, the limit of detection (LOD) and limit of quantification (LOQ) were determined in the range of 0.3–32.0 ng.L−1 and 0.8–350.0 ng.L−1, respectively, which proves the high sensitivity of the proposed method. Furthermore, the recovery percent of the extracted analytes was concluded in the range of 97.0–99.0% after 6 and 30 days of the sampling and storage at 25 °C and 4 °C, respectively. Finally, the designed procedure was employed in the analysis of the above-mentioned aromatic amines in the real urine samples. The achieved results illustrate that the three-component absorbent system (nHA;Ze;MOF@NTD) can be introduced as an efficient, fast-response, sensitive, and versatile procedure for trace analysis of the different aromatic amine c
پژوهشگران فائزه مهرگان (نفر ششم به بعد)، هومن سرکان (نفر ششم به بعد)، دانیال سلیمانی قوژدی (نفر پنجم)، بابک پاشائی دوشتور (نفر چهارم)، علی فیروزی چاهک (نفر سوم)، خالد مورتادا (نفر دوم)، رزاق رحیم پور (نفر اول)