عنوان
|
Voltammetric Determination of Droxidopa in the Presence of Tryptophan Using a Nanostructured Base Electrochemical Sensor
|
نوع پژوهش
|
مقاله چاپ شده
|
کلیدواژهها
|
Droxidopa, Tryptophan, Ionic liquid, Carbon paste electrode, Cu-TiO2 nanocomposite, 2-(ferrocenylethynyl)fluoren-9-one
|
چکیده
|
A novel carbon paste electrode modified with Cu-TiO2 nanocomposite, 2-(ferrocenylethynyl)fluoren-9-one (2FF) and ionic liquid (IL) (2FF/Cu-TiO2/IL/CPE) was fabricated and employed to study the electrocatalytic oxidation of droxidopa, using cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV) as diagnostic techniques. It has been found that the oxidation of droxidopa at the surface of modified electrode occurs at a potential of about 295 mV less positive than that of an unmodified CPE. DPV exhibits a linear dynamic range from 5.0 × 10-8 to 4.0 × 10-4 M and a detection limit of 30.0 nM for droxidopa. Finally this modified electrode was used for simultaneous determination of droxidopa and tryptophan. Also the 2FF/Cu-TiO2/IL/CPE shows excellent ability to determination of droxidopa and tryptophan in real samples.
|
پژوهشگران
|
پوریا بی پروا (نفر ششم به بعد)، رحمان حسین زاده (نفر پنجم)، سمیه تاجیک (نفر چهارم)، هادی بیت اللهی (نفر سوم)، شهره جهانی (نفر دوم)، حلیمه یعقوبیان (نفر اول)
|