2024 : 11 : 23
Jahan Bakhsh Raoof

Jahan Bakhsh Raoof

Academic rank: Professor
ORCID:
Education: PhD.
ScopusId:
HIndex:
Faculty: Faculty of Chemistry
Address: Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, 47416-95447, Iran
Phone: 01135302392

Research

Title
Template-directed synthesis of zeolitic imidazolate framework-8 derived Zn–Al layered double oxides decorated on the electrochemically anodized nanoporous aluminum substrate for thin film microextraction of chlorophenols followed by determination with high-performance liquid chromatography
Type
JournalPaper
Keywords
Template-directed synthesis, Chlorophenols, HPLC-UV, Thin film microextraction, Wastewater samples, ZIF-8
Year
2021
Journal JOURNAL OF CHROMATOGRAPHY A
DOI
Researchers Milad Ghani ، Jahan Bakhsh Raoof ، saeed masoum

Abstract

In this work, hierarchical ZIF-8 coated anodized aluminum foil was prepared through in situ template- directed method without addition of any zinc salt. The hierarchical sorbent was synthesized by the formation of the final HZIF-8 on the previously created layered double oxide (LDO) template. The LDO template was created by calcining the firstly in situ prepared desired layered double hydroxide (LDH) precursor coated on the electrochemically anodized porous Al foil in an air atmosphere. The microextrac- tion ability of the extracting device was studied through direct immersion thin film microextraction (DI- TFME). The extracted analytes were quantified by high-performance liquid chromatography equipped by UV detector (HPLC-UV). The present strategy was used for the simultaneous extraction and quantification of four selected chlorophenols (CPs) (as model analyte). The variables of the TFME were optimized using response surface methodology (Plackett-Burman and Box-Behnken design). Under the obtained optimum condition, the prepared film presented acceptable extraction properties including low limits of detection (0.03-0.22 μgL −1 ), good linear ranges (0.2–200 μgL −1 , r 2 > 0.9918) and satisfactory reproducibility (rel- ative standard deviation, 3.6 < RSD < 5.8% for one film as inter- and intra-day RSD, 4.8 < RSD < 5.3% for film to film). Moreover, the obtained enrichment factors were in the range of 56-76. The kinetics and adsorption isotherm of the selected analytes adsorption to the prepared sorbent were also investigated. The maximum adsorption capacities of the selected analytes on the prepared sorbent were in the range of 26.4-80.1 mg g −1 . The adsorption isotherm obeyed the Langmuir and Freundlich models. Moreover, the adsorption of the selected chlorophenols on the prepared film followed the pseudo-second-order kinetic model. Finally, the HZIF-8 film was utilized for the quantification of selected CPs in different types of wa- ter and wastewater samples. The